CRI Pod & Container Metrics
Kubernetes v1.23 [alpha]
The kubelet collects pod and
container metrics via cAdvisor. As an alpha feature,
Kubernetes lets you configure the collection of pod and container
metrics via the Container Runtime Interface (CRI). You
must enable the PodAndContainerStatsFromCRI
feature gate and
use a compatible CRI implementation (containerd >= 1.6.0, CRI-O >= 1.23.0) to
use the CRI based collection mechanism.
CRI Pod & Container Metrics
With PodAndContainerStatsFromCRI
enabled, the kubelet polls the underlying container
runtime for pod and container stats instead of inspecting the host system directly using cAdvisor.
The benefits of relying on the container runtime for this information as opposed to direct
collection with cAdvisor include:
-
Potential improved performance if the container runtime already collects this information during normal operations. In this case, the data can be re-used instead of being aggregated again by the kubelet.
-